Description
Superior Features
- Inbuilt Auto Sequence Allows 100 Intelligent Memory Program System 12 Desire Ramp/ Sequence Steps
- Temperature Control Range: 100° C to 440°C, Temperature Repeatability : 1 ° C.
- Live PC graphical representation with Time/ Temperature gradient, Digital LCD display.
- Time & Temperature Readout in the Digital LCD Display System.
- Audible “ Ready” & “cycle over” alerts to indicate the completion of digestion System.
- Exhaust Manifold System for Removing acid Fumes with High Grade Teflon with Viton Mix Flexible Adaptors Fitted on to a Stainless Steel Rack (Anti corrosive & Heat Resistant)
- Automatic Scrubber On & Off with Delay off Timer.
- Time setting per Ramp (Step):1-999 min.
- All essential accessories like Digestion Tubes, acid proof SS Insert Rack, Exhaust Manifold, Suction assembly for safe removal of acid fumes with easy drain Suction pump wall mounted in the system
Safety Features
Auto heater cut-off facility after completion of Digestion Cycle with indicators with visual Display.
Auto alarm for user’s attention, Over Temperature Protection, Auto sensor Break Protection
Auto Over temp. Cut Off, Acoustic and Visual error Indication & Sensor Break Detection
Automatic Scrubber System
Model: KjelSCRB Acid Neutralizer Four Stage Based Scrubbing System
First stage: Acid Fume trap condensation
Second Stage: Neutralization in Alkali
Third stage: Neutralization in water
Fourth Stage: Mechanism for dissolution of air free of acid fumes in raw tank water with add on carbon filter for removal of trace acid fumes
Vacuum Source: Non Corrosive Centrifugal Magnetic Suction Pump
Anti corrosive chemical Resistant Epoxy Powder Coated Finish
Superior Features
Fume scrubber with 28LPM capacity for complete evacuation of acid fumes.
Valve in TEFLON & Diaphragm in Teflon coated neoprene rubber.
2 litre condensation and neutralization jars for larger fume volumes.
MOC for bottles 3.3. expansion borosilicate bottles & body epoxy painted
29/32 ground glass with viton liners for quick removal
and Assembly of condenser and fume trap. Electrical requirement: 230 ± 10 Volts, 50 Hz, AC.
Threaded tube connectors for quick removal of glass components for maintenance
Transparent PC Protective front shield and easy removable bottle tray.
Carbon adsorption bottle removal any trace acid from exhaust air
Four way acid neutralization through Condenser, trapping in distilled water, trapping in
Alkali trapping & Carbon filter, Automatic Scrubber On & Off with Delay off Timer
Sound damping foam to minimize noise during operation.
Vacuum Pump for water circulation for long life of the pump
Automatic cooling water cut off post process completion for water saving.
Accessories
Borosilicate Alkali with 2 Ltr Container
Borosilicate Water with 2 Ltr Container
Automatic Distillation System
MODEL KjelDIST AT :Advanced Fully Automatic Nitrogen Distillation System (The Rapid Fully Auto Run completely Microprocessor Programmable Based Auto Sequence Operation Color TOUCH SCREEN LCD Display Distillation System with 100 Programmable user In built Software)
Color Touch Screen Display high resolution TFT LCD Display Large 7” inch touch screen
Pre definable user storage Auto sequence programmes with following Sequence steps
1) Auto Addition of Boric acid (Receiver Solution)
2) Auto Sample Selection Library
3) Auto Addition of Sample (water)Dilution
4) Auto Duration of React time
5) Auto Duration for delay time
6)Auto Addition of NaOH (Alkali)
7) Auto Duration of Neutralization.
8) Auto Addition of water Steam injection.
9) Auto Duration for Residue Removal (Tube Drain)
10) Auto Distillate control with adjustable volume Steps
11) Auto Duration of Sample Settle Time.
12) Auto Process over Intimation with alarm
13)Auto alarm for Sequence steps
14) Auto Titration Connectivity feature for Future up gradation
Superior Features
- Stainless steel non corrosive steam generator, expansion vessel and water condenser with safety sensors
- Built in steam generator with separate line for deionized / Distilled water or tap water.
- Auto Microprocessor Programmable Monitoring & measuring of high temperature protection with help of Platinum sensor & alert intimation for User attention. Continuously measured temperature is displayed digitally.
- Analysis time: 3.5 to 5 minutes Per sample (Depends upon the sample), Distillation time: 3.5 min at 30 mg N (6.5 min at 200 mg N).
- User Alert Auto Service Maintenance for periodical checking & maintenance of pumps to avoid future repairs.
- Auto Adjustable steam power from 10 to 100% directly steam inject in the sample test tube
- Auto Reagent level sensor that indicates refilling for low levels of water, alkali and boric acid.
- Full Process visibility, visual control and close monitoring of the distillation process through glass splash protector.
- Control panel unit along with inbuilt temperature controller, timer, mother board ,SMPS isolated in separate control Tower compartment to Protect electronics from wet chemistry & acid/alkali process area
- Reproducibility: 1% RSD (including the digestion step).
- Nitrogen recovery >99.5% at nitrogen levels between 1 -200 mg N
- Nitrogen levels of 0.1-200mg (Min / Max Detection Limit).
Safety Features
- Auto tube inserts error indication
- Interlocked safety protection door with safety switch
- Safety Auto Door opens warning alarm with visual Indication
- Sequence step intimation alarm/ indication for user attention
- Auto Deactivation of System Error Diagnosis, Etc.,
- Automatic Excess pressure release safety valve
- Automatic over temperature protection of heater
- Adjustable steam power from 10 to 100%













Reviews