Description
Automatic Scrubber System
First Stage: Neutralization in Alkali
Second Stage: Neutralization in water
Third stage: Dissolution with Raw Water
Non Corrosive-Chemical Resistant inbuilt Centrifugal Magnetic Self priming water Recirculation pump in 8 litres tank avoids Requirement of running water during digestion.
Integrated automatic scrubber with inbuilt timer with auto drain of tank water after every batch of digestion.
System Description Distillation System
Advanced Fully Automatic Nitrogen Distillation System (The Rapid Fully Auto Run Completely Microprocessor Programmable Based Auto Sequence Operation TFT Touch screen LCD Display Distillation System with 100 Programmable user In built Software).
Color Touch Screen Display High Resolution TFT LCD Display Large 7’ inch Screen.
Electrical Requirements:230V/50Hz.
User Storage Auto Sequence Programme Steps
Auto Customized sample library like Soil, Plant, Water, Cereals, standard sample etc.
Auto Addition of Sample Dilution
Auto Duration of React time
Auto Duration for delay time
Auto Addition of NaOH (Alkali)
Auto Duration of Neutralization
Auto Addition of water Steam injection
Auto Duration of Sample Settle Time
Auto Process over Indication with alarm with Inbuilt Delay Time Features
Auto alarm for Sequence steps
Each Sequence Run with inbuilt auto delay time features
Superior Features
- Robust Stainless steel non corrosive steam generator, expansion vessel and transparent condenser with safety sensors.
- Transparent window to watch process of distillation and splash head, Automatic Digestion, Scrubber, and Distillation with Automatic Steam & Alkali Addition Microprocessor based controller system
- Auto sequencing addition of reagent, steam processing with auto shut down of process
- Control panel unit along with inbuilt temperature controller, timer, mother board ,SMPS isolated in separate control Tower compartment to protect electronics from wet chemistry & acid/alkali process area
- Auto reagent Level Sensor with Reagents alarm, Inbuilt peristaltic pump for Reagent Addition of Alkali & Boric Acid.
- Instrument Operation can run with Digestion & Distillation (or) Independently with common panel
- Separate isolated Temperature Controller in a control tower for digestion, Distillation & Scrubber heat zone and acid Reaction chamber for safe operation
- Nitrogen level : 0.1 to 200 mg Nitrogen (Min / Max Detection Limit).
- Nitrogen Reproducibility: ± 0.1% RSD ,Nitrogen Recovery : > 99.5%.
Safety Features
Auto deactivation of system on error diagnosis
Automatic door open warning indication
Automatic over temperature protection of heater
Automatic Excess pressure release safety valve