User storage Auto sequence program Functions
- Auto Addition of Boric acid (Receiver Solution).
- Auto Sample Selection Library
- Auto Addition of Sample Dilution
- Auto Duration of React time
- Auto Duration for delay time
- Auto Addition of NaOH (Alkali)
- Auto Duration of Neutralization
- Auto Addition of water Steam injection.
- Auto Distillate control with adjustable volume Steps (50,100,150ml etc)
- Auto Duration of Sample Settle Time.
- Auto Process over Intimation with alarm
- Auto alarm for Sequence steps
- Auto Titration Connectivity feature for Future Upgradatiion
- Each Sequence run with inbuilt auto delay time feature
Superior Features
Transparent view window to watch the distillation process, sample contamination, cooling condenser and distribution splash head.
100 User Storage with 50 Pre Method Programme & 50 Method Pre Pgogramme
According to official methods & Results Continue with DIN EN, ISO, AOAC, EPA, ASTM, EC.
Electronic components by provision of over current circuit breaker and SELV (Safety Extra Low Voltage).
Microprocessor based username & Password sequence available at the time of Initial running of the instrument.
Microprocessor Based Programme method and Sample library such as Soil , Plant , food, Dairy, feed, Grains, starch cereals, fertilizer, water , others
Inbuilt LED light in distillation chamber to view distillation process, Detection limit& distillation time – 0.1mg, 2-4min/sample
Microprocessor based Inbuilt Cooling water Control System Automatic sensor detects the water Circulation in condenser, the system will intimates with auto user alarm & Visual indication. An audit trail is typically built into the software of electronic and automated in our instrument
Microprocessor based Adjustable steam power from 10-100% suitable for different applications
Provision to feed Sample data, sample number, sample status, method, sample weight, analysis date etc in Touch Screen Display
Facility to record and store statistical data of Total running cycle of pumps, Total running time of pumps, Total number of distillation completed with LCD display of all parameters. User Alert Auto Service Maintenance for periodical checking & maintenance of pumps to avoid future repairs
Auto reagent Level Sensor with Alarm for Reagents tanks to be wall mounted for easy handling and users visibility
Automatic monitoring and measuring of high temperature in distillate with alarm & warning signal. Continuously measured temperature is displayed digitally
4 USB port, 1 No-RS 232 & Ethernet interface facility for communication, printer connectivity / PC Connectivity
Direct calculation of results in LCD touch screen with user programmable formulae for direct reading of Nitrogen, protein, available Nitrogen, etc with inbuilt software
Control panel unit along with inbuilt temperature controller, timer, mother board, SMPS isolated in separate control Tower compartment to Protect electronics from wet chemistry & acid/alkali process area, with separate access door for main unit & Electronic Control tower unit
Measuring Range: 0.1 to 200 mg Nitrogen (Min / Max Detection Limit), Nitrogen Reproducibility: ± 0.1% RSD, Nitrogen Recovery > 99.5%
Safety Features
Auto tube inserts error indication
Safety Auto Door opens warning alarm with visual Indication
Auto Deactivation of System Error Diagnosis, Etc
Automatic Excess pressure release safety valve
Interlocked safety protection door with safety switch
Sequence step intimation alarm/ indication for user attention
Automatic over temperature protection of heater
Adjustable steam power from 10 to 100%